235 research outputs found

    Eulerian and Lagrangian time scales of the turbulence above staggered arrays of cubical obstacles

    Get PDF
    We present results from water-channel experiments on neutrally-stable turbulent flows over staggered arrays of cubical obstacles modelling idealised urban canopies. Attention is concentrated on the vertical profiles of the Eulerian (TE) and Lagrangian (TL) time scales of the turbulence above three canopies with different plan area fractions (λP = 0.1, 0.25 and 0.4). The results show that both the streamwise and vertical components of TL increase approximately linearly with height above the obstacles, supporting Raupach’s linear law. The comparisons with the Lagrangian time scales over canyon-type canopies in the skimming flow and wake interference regimes show that the staggered configuration of cubical obstacles increases the streamwise TL, while decreasing its vertical counterpart. A good agreement has also been found between the eddy viscosities (KT) estimated by applying Taylor’s theory and the classical first order closure relating the momentum flux to the velocity gradient. The results show that KT obeys Prandtl’s theory, particularly for λP = 0.25 and 0.4

    Flow dynamics in a model of a dilated thoracic aorta prior to and following prosthetic replacement

    Get PDF
    We numerically investigate the flow dynamics in a model of a dilated thoracic aorta, and compare the flow features with the case of a prosthetic replacement in its ascending part. The flow is characterized by an inlet jet which impacts the aortic walls and sweeps toward the aortic arch. Secondary flows generated by the transvalvular jet evolve downstream into a helical flow. The small curvature radius at the end of the aortic arch induces flow separation and vortex shedding in the initial part of the descending aorta, during the systole. The implantation of a prosthesis determines several modifications in the global and local flow patterns. An increase of the pulse wave velocity in the aorta leads to larger pressures inside the vessel, due to the geometrical and rigidity modifications. The sweeping jet is more aligned along the axial direction and propagates faster along the aortic arch. Consequently, a stronger separation of the flow downstream of the aortic arch is observed. By also exploiting manifold analysis, we identify regions characterized by near-wall disordered flows which may present intense accumulation and drop of concentration of biochemicals. These regions are localized downstream of the prosthetic replacement, in the aortic arch, and may be more prone to a new emergence of vessel dilation

    Can wall shear-stress topology predict proliferative vitreoretinopathy localization following pars plana vitrectomy?

    Get PDF
    We numerically study the fluid dynamics of oil tamponade in models of vitrectomized eyes prompted by a subset of daily activities corresponding to movements on the horizontal plane with the patient in a standing position. Bulk flow features are related to near-wall flow topology and transport at the retinal surface through a wall shear-stress-based analysis. Proliferative VitreoRetinopathy (PVR) is the leading cause of retinal re-detachment occurring in about 20% of all cases due to the accumulation of inflammatory cells in discrete retinal regions. Signalling soluble mediators stimulate inflammatory cells’ chemotaxis and studying their distribution across the retinal surface may acquire clinical relevance. In all the investigated cases, persistent and elongated regions along the retina, potentially prone to accumulate chemo-attractants and cells are observed. Gradients of soluble inflammation mediators present in the aqueous are known responsible for the so-called epithelial-mesenchymal transition that initiates PVR and favours recurrent retinal detachment prompting the proliferation of inflammatory cells with collagen matrix deposition and its contraction. The surgical apposition of encircling scleral buckling elements, known for over a century to influence PVR formation and localization, modifies the attracting regions, possibly causing an accumulation of molecules and cells along approximately vertical lines that follow the rising menisci due to the cerclage indentation. The resulting spatial pattern is compatible with clinical observations. This study may open toward rational analyses of near-wall transport to predict PVR pathogenesis by relating biochemical accumulation in certain areas of the retina to clinical conditions

    Silicone Oil Tamponade Removal: Which Technique Is More Effective? An X-Ray Photoemission Spectroscopy Study

    Get PDF
    Purpose: To compare the efficacy of two surgical techniques used to remove silicone oil (SiO) emulsion tamponade after pars plana vitrectomy: triple air–fluid exchange (AFX) and balanced salt solution lavage (BSSL). Methods: X-ray photoemission spectroscopy measured silicon content of the dry residue of fluid samples taken during AFX and BSSL. Ten patients underwent AFX and five BSSL. Three fluid samples were taken per patient, and the dry residue of 10 drops per sample were analyzed. A fluid sample from a patient who never received SiO tamponade was also analyzed to set a “blank” reference sample. Results: Patients’ demographics showed no significant difference. Sample 1 of the two groups contained comparable silicon content while samples 2 and 3 of the AFX group contained significantly more silicon than that of the BSSL group (15.0 ± 0.1 and 12.0 ± 0.9 for the AFX group vs. 10.7 ± 1.4 and 5.2 ± 0.6 for the BSSL group, respectively; P < 0.05). The cumulative amount of silicon in the three successive samples was also significantly higher for the AFX group (42.3 ± 1.6 vs. 32 ± 2; P < 0.0001). The average silicon content ratio of consecutive samples was significantly higher for the AFX group compared to the BSSL group (0.90 ± 0.01 vs. 0.58 ± 0.06; P = 0.006). Conclusions: Triple AFX removed more silicon than triple lavage. The eye wall actively interacts with silicon emulsion retaining silicon content rather than behaving as a neutral container. Translational Relevance: Triple air–fluid exchange removed more silicon than BSS lavage. Neither technique behaved as a well-mixed box dilution, suggesting the eye walls actively retain emulsion and a dynamic equilibrium is established between silicon dispersion and the eye wall surface

    Human Vitreous Collagen Fragments Dimension As a Function of Vitrectomy Cut Rate

    Get PDF
    Purpose: To study the dimensions and distribution of human vitreous collagen type II fragments collected after vitrectomy performed at varying cut rates and to evaluate if increasing the cut rate produces smaller collagen fragments, thus reducing retinal traction and/or viscosity. Methods: Fluid was collected during core vitrectomies performed for macular surgery at cut rates from 1000 to 16,000 cuts per minute (CPM) and immediately refrigerated. Protein fractions were separated by molecular weight (MW; >100 kDa, 50–100 kDa, 50– 30 kDa, 30–10 kDa, and <10 kDa) through centrifugal filters. The Human Collagen II ELISA Kit colorimetric assay was then used to measure the COL2A1 in unfiltered and filtered samples. Results: Vitreous samples collected after vitrectomy performed at 16,000 CPM contained a higher concentration of protein with MW over 100 kDa than at any other cutting frequency (P < 0.01). No significant differences were found in fractions collected with a MW between 50 and 100 kDa. Collagen type II fragments over 100 kDa were significantly more represented than smaller fragments at each cut rate. The proportion of smaller (50–100 kDa) collagen fragments compared with those over 100 kDa was higher at 2000 CPM than at higher cut rates. Conclusions: Vitreous samples collected at different cut rates do not contain a significantly different proportion of collagen type II fragments of the tested MW. The extreme variability of vitreous flowthrough the cutter port may explain the uncertain predictability of collagen fragment MWs. Translational Relevance: Increasing the cut rate does not produce vitreous fragments of proportionally smaller dimension. It is necessary to achieve an invariant instantaneous flow through the cutter port in order to decrease retinal traction during vitrectomy

    Neuroendocrine neoplasms of the breast: diagnostic agreement and impact on outcome

    Get PDF
    The classification of breast neuroendocrine neoplasms (Br-NENs) was modified many times over the years and is still a matter of discussion. In the present study, we aimed to evaluate the diagnostic reproducibility and impact on patient outcomes of the most recent WHO 2019 edition of breast tumor classification, namely, for neuroendocrine tumors (NETs) and neuroendocrine carcinomas (NECs). This multicentric observational study included 287 breast neoplasms with NE differentiation. The cases were blindly classified by three independent groups of dedicated breast and/or endocrine pathologists following the 2019 guidelines. Diagnostic concordance and clinical impact were assessed. We observed only a moderate overall diagnostic agreement across the three centers (Cohen’s kappa 0.4532) in distinguishing NET from solid papillary carcinomas (SPCs) and no special type carcinomas (NST) with NE differentiation. Br-NENs were diagnosed in 122/287 (42.5%) cases, subclassified as 11 NET G1 (3.8%), 84 NET G2 (29.3%), and 27 NEC (9.4%), the latter group consisting of 26 large-cell and 1 small-cell NECs. The remaining 165/287 (57.5%) cases were labeled as non-NEN, including SPC, mucinous, NST, and mixed NE carcinomas. While NET and non-NEN cases had a comparable outcome, the diagnosis of NECs showed negative impact on disease-free interval compared to NETs and non-NENs (p = 0.0109). In conclusion, the current diagnostic classification of Br-NENs needs further adjustments regarding morphological and immunohistochemical criteria to increase the diagnostic reproducibility among pathologists. Our data suggest that, apart from high-grade small- and large-cell NECs, Br-NENs behave like non-NEN breast carcinomas and should be managed similarly

    An immunohistochemically positive E-cadherin status is not always predictive for a good prognosis in human breast cancer

    Get PDF
    BACKGROUND: in primary breast cancers dichotomic classification of E-cadherin expression, according to an arbitrary cutoff, may be inadequate and lead to loss of prognostic significance or contrasting prognostic indications. We aimed to assess the prognostic value of high and low E-cadherin levels in a consecutive case series (204 cases) of unilateral node-negative non-lobular breast cancer patients with a 8-year median follow-up and that did not receive any adjuvant therapy after surgery. METHODS: expression of E-cadherin was investigated by immunohistochemistry and assessed according to conventional score (0, 1+, 2+, 3+). Multiple correspondence analysis was used to visualise associations of both categorical and continuous variables. The impact of E-cadherin expression on patients outcome was evaluated in terms of event-free survival curves by the Kaplan-Meier method and proportional hazard Cox model. RESULTS: respect to intermediate E-cadherin expression values (2+), high (3+) or low (0 to 1+) E-cadherin expression levels had a negative prognostic impact. In fact, both patients with a low-to-nil (score 0 to 1+) expression level of E-cadherin and patients with a high E-cadherin expression level (score 3+) demonstrated an increased risk of failure (respectively, hazard ratio (HR)=1.71, confidence interval (CI)=0.72-4.06 and HR=4.22, CI=1.406-12.66) and an interesting association with young age. CONCLUSIONS: the findings support the evidence that high expression values of E-cadherin are not predictive for a good prognosis and may help to explain conflicting evidence on the prognostic impact of E-cadherin in breast cancer when assessed on dichotomic basis

    Image analysis techniques for the study of turbulent flows

    Get PDF
    In this paper, a brief review of Digital Image Analysis techniques employed in Fluid Mechanics for the study of turbulent flows is given. Particularly the focus is on the techniques developed by the research teams the Author worked in, that can be considered relatively "low cost" techniques. Digital Image Analysis techniques have the advantage, when compared to the traditional techniques employing physical point probes, to be non-intrusive and quasi-continuous in space, as every pixel on the camera sensor works as a single probe: consequently, they allow to obtain two-dimensional or three-dimensional fields of the measured quantity in less time. Traditionally, the disadvantages are related to the frequency of acquisition, but modern high-speed cameras are typically able to acquire at frequencies from the order of 1 KHz to the order of 1 MHz. Digital Image Analysis techniques can be employed to measure concentration, temperature, position, displacement, velocity, acceleration and pressure fields with similar equipment and setups, and can be consequently considered as a flexible and powerful tool for measurements on turbulent flows

    Pre-operative management of Pleomorphic and florid lobular carcinoma in situ of the breast: Report of a large multi-institutional series and review of the literature

    Get PDF
    Background: Pleomorphic and Florid Lobular carcinoma in situ (P/F LCIS) are rare variants of LCIS, the exact nature of which is still debated. Aim: To collect a large series of P/F LCIS diagnosed on preoperative biopsies and evaluate their association with invasive carcinoma and high grade duct carcinoma in situ (DCIS). Data obtained were compared with those reported in the literature. Methods: A multi-institutional series of P/F LCIS was retrieved. All cases were diagnosed on pre-operative biopsies, which was followed by an open surgical excision. Data on post-operative histopathology were available. A literature review was performed. Results: A total of 117 cases were collected; invasive carcinoma and/or DCIS was present in 78/117 cases (66.7%). Seventy cases of P/F LCIS were pure on biopsy and 31 of these showed pathological upgrade in post-surgical specimens. Pre-operative biopsy accuracy was 47/78 (60.3%); pre-operative biopsy underestimation of cancer was 31/78 (39,7.%). In the literature review papers, invasive carcinoma or DCIS was associated with 274 of 418 (65.5%) cases of P/F LCIS. Pre-operative biopsy accuracy was 66% (181/274) whereas pre-operative biopsy underestimation of cancer was 33.9% (93/274). Conclusions: The data presented here indicate that P/F LCIS is frequently associated with invasive carcinoma or high grade DCIS and that pre-operative biopsy is associated with an underestimation of malignancy. Open surgery is indicated when P/F LCIS is diagnosed pre-operatively
    • …
    corecore